微创内固定治疗骨盆损伤新进展 |
上海交通大学附属第六人民医院骨科,200233 |
|
Noval advancement in research of minimallyinvasive internal fixation for pelvic injuries |
| [1]Kellam JF, McMurtry RY, Paley D, et al. The unstable pelvic fracture. Operative treatment. Orthop Clin North Am, 1987, 18(1):25-41.
|
| [2]Routt ML Jr, Simonian PT, Swiontkowski MF. Stabilization of pelvic ring disruptions. Orthop Clin North Am, 1997, 28(3):369-388.
|
| [3]Routt ML Jr, Simonian PT, Grujic L. The retrograde medullary superior pubic ramus screw for the treatment of anterior pelvic ring disruptions: a new technique. J Orthop Trauma, 1995, 9(1):35-44.
|
| [4]Mosheiff R, Liebergall M. Maneuvering the retrograde medullary screw in pubic ramus fractures. J Orthop Trauma, 2002, 16(8):594-596.
|
| [5]Akagi M, Ikeda N, Fukiage K, et al. A modification of the retrograde medullary screw for the treatment of bilateral pubic ramus nonunions: a case report. J Orthop Trauma, 2002, 16(6):431-433.
|
| [6]Rubel IF, Seligson D, Mudd L, et al. Endoscopy for anterior pelvis fixation. J Orthop Trauma, 2002, 16(7):507-514.
|
| [7]Zobrist R, Messmer P, Levin LS, et al. Endoscopic-assisted, minimally invasive anterior pelvic ring stabilization: a new technique and case report. J Orthop Trauma, 2002, 16(7):515-519.
|
| [8]孙玉强, 唐明杰, 宋文奇, 等. 有限切开复位内固定治疗Tile C型骨盆骨折. 中华创伤骨科杂志, 2012, 14(5):395-398.
|
| [9]Sagi HC, Ordway NR, DiPasquale T. Biomechanical analysis of fixation for vertically unstable sacroiliac dislocations with iliosacral screws and symphyseal plating. J Orthop Trauma, 2004, 18(3):138-143.
|
| [10]Starr AJ, Nakatani T, Reinert CM, et al. Superior pubic ramus fractures fixed with percutaneous screws: what predicts fixation failure? J Orthop Trauma, 2008, 22(2):81-87.
|
| [11]Vaidya R, Colen R, Vigdorchik J, et al. Treatment of unstable pelvic ring injuries with an internal anterior fixator and posterior fixation: initial clinical series. J Orthop Trauma, 2012, 26(1):1-8.
|
| [12]Hiesterman TG, Hill BW, Cole PA. Surgical technique: a percutaneous method of subcutaneous fixation for the anterior pelvic ring: the pelvic bridge. Clin Orthop Relat Res, 2012, 470(8):2116-2123.
|
| [13]Cole PA, Gauger EM, Anavian J, et al. Anterior pelvic external fixator versus subcutaneous internal fixator in the treatment of anterior ring pelvic fractures. J Orthop Trauma, 2012, 26(5):269-277.
|
| [14]Moazzam C, Heddings AA, Moodie P, et al. Anterior pelvic subcutaneous internal fixator application: an anatomic study. J Orthop Trauma, 2012, 26(5):263-268.
|
| [15]Routt ML Jr, Nork SE, Mills WJ. Percutaneous fixation of pelvic ring disruptions. Clin Orthop Relat Res, 2000, (375):15-29.
|
| [16]Starr AJ, Walter JC, Harris RW, et al. Percutaneous screw fixation of fractures of the iliac wing and fracture-dislocations of the sacro-iliac joint (OTA Types 61-B2.2 and 61-B2.3, or Young-Burgess “lateral compression type II”pelvic fractures). J Orthop Trauma, 2002, 16(2):116-123.
|
| [17]郭晓山, 池永龙. 经皮空心加压螺钉固定髂骨后部骨折. 中华外科杂志, 2005, 43(24):1580-1582.
|
| [18]Matta JM, Saucedo T. Internal fixation of pelvic ring fractures. Clin Orthop Relat Res, 1989, (242):83-97.
|
| [19]Ziran BH, Smith WR, Towers J, et al. Iliosacral screw fixation of the posterior pelvic ring using local anaesthesia and computerised tomography. J Bone Joint Surg (Br), 2003, 85(3):411-418.
|
| [20]孔建中, 郭晓山, 潘骏, 等. 经皮骶髂关节螺钉治疗骶骨纵形骨折. 中华创伤杂志, 2005, 21(6):410-412.
|
| [21]Griffin DR, Starr AJ, Reinert CM, et al. Vertically unstable pelvic fractures fixed with percutaneous iliosacral screws: does posterior injury pattern predict fixation failure? J Orthop Trauma, 2006, 20(1 Suppl):S30-S36.
|
| [22]van Zwienen CM, van den Bosch EW, Snijders CJ, et al. Biomechanical comparison of sacroiliac screw techniques for unstable pelvic ring fractures. J Orthop Trauma, 2004, 18 (9):589-595.
|
| [23]van den Bosch EW, van Zwienen CM, van Vugt AB. Fluoroscopic positioning of sacroiliac screws in 88 patients. J Trauma, 2002, 53(1):44-48.
|
| [24]Hamelinck HK, Haagmans M, Snoeren MM, et al. Safety of computer-assisted surgery for cannulated hip screws. Clin Orthop Relat Res, 2007, (455):241-245.
|
| [25]杜明奎, 王秋根. 锁定加压钢板固定骶骨不稳定骨折的应用及三维有限元分析. 中国骨与关节损伤杂志, 2008, 23(10):793-795.
|
| [26]黄涛, 周东生, 吕荷荣, 等. 骶骨棒微创小切口治疗骶骨纵行骨折. 中国矫形外科杂志, 2006, 14(16):1218-1220.
|
| [27]Gardner MJ, Routt ML Jr. Transiliac-transsacral screws for posterior pelvic stabilization. J Orthop Trauma, 2011, 25(6):378-384.
|
| [28]Deen HG, Nottmeier EW. Balloon kyphoplasty for treatment of sacral insufficiency fractures. Report of three cases. Neurosurg Focus, 2005, 18(3):e7.
|
|
|
|