Abstract:Objective To assess whether highly cross-linked polyethylene liners are superior to conventional polyethylene liners in total hip arthroplasty (THA).Methods Randomized controlled trials (RCTs) of highly cross-linked and conventional polyethylene liners in THA were retrieved from MEDLINE,PubMed,EMBASE,Cochrane Central,CBMdisc,CBM,and VIP.Until April 2012,reference lists of the included articles and related reviews were manually searched as supplements.Meta analysis was performed with RevMan 5.1.Mean difference (MD) was used to assess the linear wear rate in highly cross-linked group versus conventional group.Odds ratio (OR) was used to estimate the osteolysis and revision incidence in the two groups.Results Meta analysis indicated that the two-dimensional linear wear rate [MD =-0.08,95% CI (-0.1,0.06),P < 0.05],three-dimensional linear wear rate [MD=-0.15,95%CI (-0.22,0.08),P<0.05],volumetric wear rate [MD=-53.03,95% CI (-84.39,-21.67,P<0.05],total linear wear [MD=-0.19,95%CI (-0.23,-0.15),P<0.05],and osteolysis incidence [OR =0.23,95% C1 (0.13,0.39),P < 0.05] were significantly reduced in highly cross-linked group than in conventional group.There were no statistical differences between the two groups concerning the creep value of the polyethylene liners and revision incidence.Conclusions Highly cross-linked polyethylene liners for primary THA present a low incidence of wear and osteolysis.As the number and quality of the included studies are limited,a long-term follow-up of more large-sample and high-quality RCTs are needed to evidence the outcome.
. Meta-analysis of use of highly crosslinked and conventional polyethylene liners in total hip arthroplasty[J]. CHINESE JOURNAL OF TRAUMA, 2013, 29(12): 1163-1169.
[1]Harris WH. The problem is osteolysis. Clin Orthop Relat Res, 1995, (311):46-53.
[2]Sochart DH. Relationship of acetabular wear to osteolysis and loosening in total hip arthroplasty. Clin Orthop Relat Res, 1999, (363):135-150.
[3]Muratoglu OK, Bragdon CR, O’connor DO,et al. A novel method of cross-linking ultra-high-molecular-weight polyethylene to improve wear, reduce oxidation, and retain mechanical properties. Recipient of the 1999 HAP Paul Award. J Arthroplasty, 2001, 16(2):149-160.
[4]Ingram JH, Stone M, Fisher J, et al. The influence of molecular weight, crosslinking and counterface roughness on TNF-alpha production by macrophages in response to ultra high molecular weight polyethylene particles. Biomaterials, 2004, 25(17):3511-3522.
[5]Calvert GT, Devane PA, Fielden J, et al. A double-blind, prospective, randomized controlled trial comparing highly cross-linked and conventional polyethylene in primary total hip arthroplasty.J Arthroplasty, 2009,24(4):505-510.
[6]Digas G,Karrholm J, Thanner J, et al. 5-year experience of highly cross-linked polyethylene in cemented and uncemented sockets: two randomized studies using radiostereometric analysis. Acta Orthop, 2007, 78(6):746-754.
[7]Digas G, Krrholm J, Thanner J, et al. The Otto Aufranc Award. Highly cross-linked polyethylene in total hip arthroplasty: randomized evaluation of penetration rate in cemented and uncemented sockets using radiostereometric analysis. Clin Orthop Relat Res, 2004, (429):6-16.
[8]Engh CA Jr, Stepniewski AS, Ginn SD, et al. A randomized prospective evaluation of outcomes after total hip arthroplasty using cross-linked marathon and non-cross-linked Enduron polyethylene liners.J Arthroplasty, 2006, 21(6 Suppl 2):17-25.
[9]García-Rey E, García-Cimbrelo E, Cruz-Pardos A, et al. New polyethylenes in total hip replacement: a prospective, comparative clinical study of two types of liner. J Bone Joint Surg (Br), 2008, 90(2):149-153.
[10]Geerdink CH, Grimm B, Ramakrishnan R, et al. Crosslinked polyethylene compared to conventional polyethylene in total hip replacement: pre-clinical evaluation, in-vitro testing and prospective clinical follow-up study. Acta Orthop, 2006, 77(5):719-725.
[11]Geerdink CH, Grimm B, Vencken W, et al. Cross-linked compared with historical polyethylene in THA: an 8-year clinical study. Clin Orthop Relat Res, 2009, 467(4):979-984.
[12]Glyn-Jones S, McLardy-Smith P, Gill HS, et al. The creep and wear of highly cross-linked polyethylene: a three-year randomised, controlled trial using radiostereometric analysis. J Bone Joint Surg (Br), 2008, 90(5):556-561.
[13]Ise K, Kawanade K, Tamura J, et al. Clinical results of the wear performance of cross-linked polyethylene in total hip arthroplasty: prospective randomized trial. J Arthroplasty, 2009, 24(8):1216-1220.
[14]Mutimer J, Devane PA, Adams K, et al. Highly crosslinked polyethylene reduces wear in total hip arthroplasty at 5 years. Clin Orthop Relat Res, 2010, 468(12):3228-3233.
[15]McCalden RW, MacDonald SJ, Rorabeck CH, et al. Wear rate of highly cross-linked polyethylene in total hip arthroplasty. A randomized controlled trial. J Bone Joint Surg (Am), 2009, 91(4):773-782.
[16]Triclot P, Grosjean G, Masri FE, et al. A comparison of the penetration rate of two polyethylene acetabular liners of different levels of cross-linking. A prospective randomised trial. J Bone Joint Surg (Br), 2007, 89(11):1439-1445.
[17]Martell JM, Verner JJ, Incavo SJ. Clinical performance of a highly cross-linked polyethylene at two years in total hip arthroplasty: a randomized prospective trial. J Arthroplasty, 2003, 18(7 Suppl 1):55-59.
[18]Thomas GE, Simpson DJ, Mehmood S, et al. The seven-year wear of highly cross-linked polyethylene in total hip arthroplasty: a double-blind, randomized controlled trial using radiostereometric analysis. J Bone Joint Surg (Am), 2011, 93(8):716-722.
[19]Mu Z, Tian J, Wu T, et al. A systematic review of radiological outcomes of highly cross-linked polyethylene versus conventional polyethylene in total hip arthroplasty. Int Orthop, 2009, 33(3):599-604.
[20]Kuzyk PR, Saccone M, Sprague S, et al. Cross-linked versus conventional polyethylene for total hip replacement: a meta-analysis of randomised controlled trials. J Bone Joint Surg (Br), 2011, 93(5):593-600.
[21]Bradford L, Kurland R, Sankaran M, et al. Early failure due to osteolysis associated with contemporary highly cross-linked ultra-high molecular weight polyethylene. A case report. J Bone Joint Surg (Am), 2004, 86(5):1051-1056.
[22]McKellop HA. Bearing surfaces in total hip replacements: state of the art and future developments. Instr Course Lect, 2001, 50:165-179.
[23]Harris WH, Muratoglu OK. A review of current cross-linked polyethylenes used in total joint arthroplasty. Clin Orthop Relat Res, 2005, (430):46-52.
[24]Baker DA, Bellare A, Pruitt L. The effects of degree of crosslinking on the fatigue crack initiation and propagation resistance of orthopedic-grade polyethylene. J Biomed Mater Res A, 2003, 66(1):146-154.
[25]Bradford L, Baker DA, Graham J, et al. Wear and surface cracking in early retrieved highly cross-linked polyethylene acetabular liners. J Bone Joint Surg (Am), 2004, 86-A(6):1271-1282.
[26]Muratoglu OK, Wannomae K, Christensen S, et al. Ex vivo wear of conventional and cross-linked polyethylene acetabular liners. Clin Orthop Relat Res, 2005, 438:158-164.